Vertical Pipeline Multistage High Pressure Water Centrifugal Pump Introduction: The high pressure water pump is a new generation of pump designed by incorporating the excellent features of vertical centrifugal pumps and international standards. It offers enhanced performance, reliability, and efficiency for various industrial applications. Advantages: 1. Vertical sectional and stainless steel casing structure, providing an attractive and durable appearance. 2. Combines the benefits of high pressure from traditional multi-stage pumps, offering lightweight design and saving valuable space. 3. High efficiency, energy-saving, low noise, no leakage, and easy maintenance. 4. Stable operation and long service life, ensuring reliable performance over time. Application: 1. Widely used in high-pressure systems for circulation and boosting. 2. Ideal for water supply in high-rise buildings with multiple pumps. 3. Suitable for fire fighting systems. 4. Used in boiler feed water applications. 5. Applied in cooling water systems. 6. Effective for transporting flushing fluids. GDL Vertical Pipe Multi-Stage Centrifugal Pump - Working Conditions: a) The pump can transfer fresh water or liquids similar to clear water. b) Temperature range: -15°C to +120°C. c) Working pressure: Maximum 2.5MPa; system pressure = inlet pressure + closing pressure < 2.5MPa. Features: 1. Advanced hydraulic model for high efficiency and wide performance range. 2. Easy installation and maintenance with pipe-type installation, allowing flexible valve placement. 3. Attractive design using high-quality stainless steel. 4. Low operational and maintenance costs due to high-quality mechanical seals that are wear-resistant, leak-proof, long-lasting, and have a low failure rate. Parameter: - Flow: 2 - 160 m³/h - Head: 24 - 200m - Power: 1.1 - 90 kw - Speed: 2900 r/min - Diameter: φ25 - φ150 - Medium Temperature: -15 - +120°C - Working Pressure: ≤2.5Mpa Technical Parameters Table: | NO. | Type | Diameter | Flow (m³/h) | Head (m) | Rotation (r/min) | Efficiency (%) | Motor Power (KW) | NPSH | Weight (kg) | |-----|-----------------|----------|-------------|----------|------------------|----------------|------------------|------|-------------| | 1 | 25GDL2-12×3 | 25 | 2 | 36 | 30 | 2900 | 1.1 | 1.7 | 58 | | 2 | 25GDL2-12×4 | 25 | 2 | 48 | 30 | 2900 | 1.1 | 1.7 | 62 | | 3 | 25GDL2-12×5 | 25 | 2 | 60 | 30 | 2900 | 1.5 | 1.7 | 68 | | 4 | 25GDL2-12×6 | 25 | 2 | 72 | 30 | 2900 | 1.5 | 1.7 | 72 | | 5 | 25GDL2-12×7 | 25 | 2 | 84 | 30 | 2900 | 2.2 | 1.7 | 78 | | 6 | 25GDL2-12×8 | 25 | 2 | 96 | 30 | 2900 | 2.2 | 1.7 | 82 | | 7 | 25GDL2-12×9 | 25 | 2 | 108 | 30 | 2900 | 2.2 | 1.7 | 86 | | 8 | 25GDL2-12×10 | 25 | 2 | 120 | 30 | 2900 | 3.0 | 1.7 | 98 | | 9 | 25GDL2-12×11 | 25 | 2 | 132 | 30 | 2900 | 3.0 | 1.7 | 102 | | 10 | 25GDL2-12×12 | 25 | 2 | 144 | 30 | 2900 | 3.0 | 1.7 | 106 | This detailed table provides comprehensive information on the technical specifications of the GDL vertical pipe multi-stage centrifugal pump, making it easier for users to select the most suitable model based on their specific requirements.

Commercial Heat Pump

Introduction to GENT commercial heat pump

 

The classification of GENT commercial heat pump is divided according to the applicable fields of heat pumps. As the name implies, commercial heat pump refers to heat pump products that can be used in commerce. There are many scenarios in the commercial field that require heating, cooling and hot water. Many of GENT's heat pumps can meet these needs, and the use of heat pumps for commercial buildings has very significant characteristics of high efficiency, energy saving, environmental protection and low carbon. Therefore, GENT's heat pump products can be used in the commercial field.

 

The main application scenarios of commercial heat pump system

1. Commercial building heating and cooling

Heat pumps in commercial buildings can provide heating and cooling services for commercial buildings such as office buildings, shopping malls, and hotels, replacing traditional boilers and Air Conditioning systems, reducing energy consumption and operating costs. In addition, according to the different sources used by the unit, commercial hvac heat pump that can be used in commercial buildings include commercial air source heat pump, Geothermal Ground Source Heat Pump and Water To Water Heat Pump, which can stably meet the heating and cooling needs of buildings.

2. Hot water supply

Heat pump water heater can provide efficient hot water supply for hotels, gyms, swimming pools and other places, which is more energy-efficient than traditional electric water heaters or gas boilers. Air source heat pump water heater has a wide range of applications in the commercial field, especially in places where a large amount of hot water is needed.

3. Cold chain and refrigeration

Heat pump technology can be used in commercial cold chain systems to provide refrigeration services for cold storage, supermarket refrigerators, etc., while recovering heat for other purposes.

 

Points to note

1. Although the initial investment in the commercial application of heat pumps will be relatively high, the long-term operating cost is low.

2. Users need to choose the right type of heat pump according to the specific scenario.

 

In short, commercial heat pump unit has broad application prospects in the commercial field, and commercial users with needs can consider heat pump products.

heat pumps for commercial buildings,commercial heat pump system,heat pumps in commercial buildings,commercial heat pump unit,commercial hvac heat pump

GUANGZHOU GENT NEW ENERGY TECHNOLOGY CO., LTD , https://www.gentgz.com